Authorised Representative Requirements for SAHPRA Establishment Licences

Updated: 2026-11-12 · GRZAN Regulatory Team · Verification date 2026-10-20

1. Key takeaways

Applicants for a South African Medical Device Establishment Licence must appoint and designate an Authorised Representative (AR). Under the definition in Notice 1515, the AR must be a natural person resident in the Republic of South Africa, must hold the written authorisation of the manufacturer, importer, distributor, wholesaler, retailer or service provider, must act in that entity’s name on designated matters, and is responsible for the performance, quality and safety of the devices and for compliance with registration conditions, clinical trials or clinical investigations. Each premises at which business is conducted must have its own AR. The AR is therefore not an administrative convenience but a person on whom real regulatory accountability is placed, and the choice of who fills the role shapes the quality of every later interaction with SAHPRA, from licence application through registration filings to inspection responses.

2. Legal basis

InstrumentReference numberPublication dateProvisions
Medicines and Related Substances ActAct No. 101 of 1965Enacted and published in 1965, as amended; verified as of 29 October 2026Section 22C(1)(b) (requirement to appoint and designate an Authorised Representative)
Regulations Relating to Medical Devices and In Vitro Diagnostic Medical Devices (IVDs)Government Gazette No. 40480, Notice No. 1515Published on 9 December 2016Regulation 1 definition of authorised representative (three elements under (a), (b) and (c)); Regulations 8(2) and 8(5)(a)(vii) (registration applications must state AR details and contact information); Regulation 8(7) (declaration of conformity made by the AR)
SAHPRA Medical Devices unit pagePublished on the SAHPRA websiteCurrent version, verified as of 29 October 2026Requirements section on the Authorised Representative (natural person, resident in South Africa, one per premises, responsible for compliance with laws and guidelines)
Establishment licence application formGLF-MD-06A v5September 2025AR details section; AR curriculum vitae and company letter of appointment must be attached

3. Expert insights

Insight one: natural person is a hard restriction; a company cannot serve as the AR. The definition expressly requires a natural person resident in the Republic. This means a South African subsidiary or a distributor company cannot simply be written in as the AR; a specific individual must be designated. This differs from the European Union approach, under which the authorised representative may be a legal person, and it is a distinctive feature of the South African system — as well as the pitfall most easily stumbled into by companies from the Chinese mainland preparing their first South African submission.

Insight two: the AR’s scope of responsibility goes far beyond being a mail recipient. Paragraph (c) of the definition makes the AR responsible for every aspect of the devices, including performance, quality and safety, and compliance with registration conditions and with clinical trial or clinical investigation requirements. This is a bundle of responsibilities that overlaps heavily with those of the licence holder. When selecting an AR, companies should treat the role as a substantive position rather than a nominal affiliation, and should define the boundaries of responsibility and any indemnity arrangements clearly in the letter of appointment.

Insight three: one AR per premises directly determines staffing costs. The official requirement is one AR for each premises at which business is conducted. For companies operating multiple warehouses, multiple outlets or multiple sites, the number of ARs grows linearly with the number of premises. This must be considered upfront in budget and workforce planning rather than patched after the fact, because the licence application itself must list the premises and their ARs, and adding premises later triggers amendments.

Insight four: AR information in registration and licence applications must be consistent. Regulation 8(2) requires the registration application to state the details of the South African AR responsible for communicating with the Authority; Regulation 8(5)(a)(vii) requires the application form to include the AR’s contact details; and Regulation 8(7) requires the declaration of conformity to be made by the AR. All three point to the same natural person, and any inconsistency will be picked up at formal review and returned for correction, costing weeks on a timeline that is usually already tight.

Insight five: the AR appointment documents are a fixed item at formal review. The application form requires the AR’s curriculum vitae (CV) and a letter of appointment issued by the company, and every page of the application form must be signed by the AR at the foot, with the AR section and the declaration section fully signed. Incomplete signatures are a common reason for rejection — a detail that has no direct counterpart in submission experience from the Chinese mainland, where sign-off conventions differ, so checklist discipline matters here.

4. Practical recommendations

  1. Staff ARs by premise count: map the premises first, then fix the headcount.
  2. Assess the candidate’s actual capacity to perform before appointment: the AR carries substantive responsibility.
  3. Define duties, term and product scope in the letter of appointment: and agree mechanisms for changes and termination.
  4. Have the AR sign every page of the application form: the AR section and the declarations must be fully signed.
  5. Submit the CV and the letter of appointment together: fixed annexes for formal review.
  6. Keep AR information consistent across licence, registration and labelling.

5. Verification checklist

  • □ Verify that the AR is a natural person resident in South Africa (not a corporate entity)
  • □ Verify that ARs are staffed by premise count (one per premises)
  • □ Verify that the company’s letter of appointment for the AR has been obtained (duties, term, product scope)
  • □ Verify that the AR curriculum vitae (CV) has been prepared
  • □ Verify that every page of the application form has been signed by the AR at the foot
  • □ Verify that the AR section and the declaration section are fully signed
  • □ Verify that AR information is consistent across licence, registration and labelling
  • □ Verify that written arrangements with the AR on responsibility boundaries and information flows are in place

Regulatory information verified as of 29 October 2026. The instruments, guidelines and effective dates described in this article are limited to the content published by the official sources listed under the legal basis above as at that date; where official documents are updated, the latest published version prevails.

  • South Africa local support: GRZAN assists manufacturers in the Chinese mainland and abroad with SAHPRA Medical Device Establishment Licence (MDEL) applications and product registration preparation, including Authorised Representative (AR) arrangements, ISO 13485 certification pathway planning and CAB selection, GMDN coding and classification decisions, technical documentation, and the setup of vigilance and adverse event reporting mechanisms.
  • Service capabilities: product attribute determination and risk classification (Class A, B, C, D), establishment licence applications and renewals, reliance pathway arguments, technical documentation and essential principles conformity arguments, labelling and instructions for use localisation in English, and post-market vigilance and annual compliance submissions.
  • Contact: info@grzanglobal.com; hito.lin@grzan.cn; website www.grzan.cn.

Disclaimer

Prepared by GRZAN from publicly available regulation. It is provided for general information only and does not constitute legal advice. Legislation and official fees are subject to change by the competent authority.

About GRZAN

GRZAN (Global Regulatory Zone Access Navigator) — the global market-access navigator for medical devices and IVDs.

GRZAN is a specialist consultancy for medical device and IVD market access, providing end-to-end regulatory solutions across the product lifecycle and making international market entry simpler and faster.

Key figures. More than 25 wholly owned subsidiaries worldwide covering 50+ countries and regions; chosen by 100+ listed and leading Chinese device manufacturers, with 4,000+ successful cases; 12+ years in the sector and 200+ regulatory training sessions and seminars delivered.

What we do. Global market access: multi-country registration programmes, technical documentation, regulatory advice. Clinical evidence: clinical evaluation reports (CER), usability studies, overseas clinical investigations. Quality systems: ISO 13485, MDSAP, FDA QMSR and BGMP implementation and audit readiness. Authorised representative and licence-holder services across Southeast Asia, Latin America, the Middle East, Africa, Europe and North America.

Why GRZAN. A real operating entity, with the certificate held by the manufacturer: our direct overseas subsidiaries act as the compliant local holder, so the regulatory relationship stays clear and you keep control rather than being tied to a distributor. Direct access to the team: no time-zone gap, no language barrier, no cultural gap. Review points anticipated: we know what FDA 510(k), EU MDR, Southeast Asian, Latin American and Middle Eastern reviewers look for, which shortens timelines and reduces deficiency letters. Pathway planning: pre-decision analysis and risk assessment before you commit.

Every engagement rests on three commitments: efficiency through pre-submission review, certainty through a clear pathway, and stability through a licence-holder that stays in place.

Take your devices global with GRZAN

We work with manufacturers worldwide to open new markets with a clear regulatory pathway.

Contact us
WhatsApp
QR Code
WhatsApp QR Code
Scan to chat on WhatsApp
Phone
Call
Office Mon-Fri 9:00-18:00
0755-88659477
Mobile 24/7 Service
+86 15816864648
Email
Mail