On 10 November 2026, the European Commission published two implementing decisions in the Official Journal of the European Union:
This update mainly concerns radiation sterilisation of medical devices, clinical trials, biological evaluation, washer-disinfectors, electrical safety and medical connectors.
The key changes of the two decisions are summarised below.
1. MDR Harmonised Standards Update: Multiple Technical Fields Covered
Under Implementing Decision (EU) 2026/2479, the European Commission revised the existing list of MDR harmonised standards, mainly covering the replacement of existing standards and the addition of newly harmonised standards.
1. Updates to two existing harmonised standards
In this update, two existing harmonised standards are replaced by new versions:
| Existing harmonised standard | New harmonised standard | Field covered |
|---|---|---|
| EN ISO 11137-1:2015 and A2:2019 | EN ISO 11137-1:2026 | Radiation sterilisation of medical devices |
| EN ISO 14155:2020 and A11:2024 | EN ISO 14155:2026 | Clinical investigation of medical devices in human subjects |
(1) EN ISO 11137-1:2026 – Radiation sterilisation of medical devices
Standard title: Sterilization of health care products – Radiation – Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices.
It mainly covers requirements for the development, validation and routine control of radiation sterilisation processes for medical devices.
The new version replaces EN ISO 11137-1:2015 and its amendment A2:2019.
(2) EN ISO 14155:2026 – Clinical trials of medical devices
Standard title: Clinical investigation of medical devices for human subjects – Good clinical practice.
This standard covers good clinical practice (GCP) for clinical investigations of medical devices in human subjects.
The new version replaces EN ISO 14155:2020 and its amendment A11:2024.
2. Seven new harmonised standard entries
In addition to the two standard updates above, the following harmonised standard entries have been added:
| Standard designation | Field covered | Main scope |
|---|---|---|
| EN ISO 4074:2026 | Natural rubber latex male condoms | Product requirements and test methods |
| EN ISO 10993-6:2026 | Biological evaluation of medical devices | Tests for local effects after implantation |
| EN ISO 10993-7:2026 | Biological evaluation of medical devices | Ethylene oxide sterilisation residuals |
| EN ISO 15883-6:2026 | Washer-disinfectors | Requirements and tests for thermal disinfection of non-critical medical devices and healthcare equipment |
| EN IEC 60601-2-22:2020 and A11:2026 | Medical laser equipment | Basic safety and essential performance of surgical, therapeutic, diagnostic and cosmetic laser equipment |
| EN IEC 60601-2-57:2026 and A11:2026 | Non-laser light source equipment | Equipment for therapeutic, diagnostic, monitoring, cosmetic and aesthetic uses |
| EN ISO 80369-1:2026 | Medical connectors | General requirements for small-bore connectors for liquids and gases in healthcare applications |
Among them, the following items deserve particular attention from relevant manufacturers:
EN ISO 10993-6:2026
It concerns biological evaluation of local effects after implantation of medical devices.
EN ISO 10993-7:2026
It concerns ethylene oxide (EO) sterilisation residuals and is a key standard for medical devices sterilised with EO.
EN ISO 15883-6:2026
It concerns washer-disinfectors using thermal disinfection, covering non-critical medical devices and healthcare equipment.
EN IEC 60601-2-57:2026
It concerns non-laser light source equipment, covering therapeutic, diagnostic, monitoring, cosmetic and aesthetic uses.
These standards have been added to the MDR harmonised standards list; manufacturers may assess their applicability according to product type and the scope of each standard.
2. IVDR Harmonised Standards Update: Radiation Sterilisation Standard Updated in Parallel
Under Implementing Decision (EU) 2026/2481, the European Commission amended the IVDR harmonised standards list (EU) 2021/1195.
This IVDR update mainly concerns one standard:
EN ISO 11137-1:2026
| Existing harmonised standard | New harmonised standard | Field covered |
|---|---|---|
| EN ISO 11137-1:2015 and A2:2019 | EN ISO 11137-1:2026 | Radiation sterilisation of healthcare products |
Title of the new version:
Sterilization of health care products – Radiation – Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices.
It mainly covers:
- Development of radiation sterilisation processes;
- Validation of sterilisation processes;
- Routine control of sterilisation processes.
The decision removes the harmonised standards references to EN ISO 11137-1:2015 and its amendment A2:2019, and adds EN ISO 11137-1:2026.
Note that this IVDR decision mainly updates the radiation sterilisation standard and does not include other newly harmonised standards.
3. Key Date: 10 May 2028
Both implementing decisions were published in the Official Journal of the European Union on 10 November 2026 and entered into force on the date of publication.
However, the European Union has set a transition period for the withdrawal of references to the existing harmonised standards.
| Item | MDR (2026/2479) | IVDR (2026/2481) |
|---|---|---|
| Date of adoption of the decision | 9 November 2026 | 9 November 2026 |
| Date of publication in the Official Journal | 10 November 2026 | 10 November 2026 |
| Date of entry into force | 10 November 2026 | 10 November 2026 |
| Applicability date for removal of references to the old standards | 10 May 2028 | 10 May 2028 |
Important note:
10 May 2028 is not a unified entry-into-force date for all new harmonised standards.
According to the specific provisions of the two decisions:
- In the MDR decision, points (1) and (3) of the Annex, i.e. the arrangements for removing references to the old versions of EN ISO 11137-1 and EN ISO 14155, apply from 10 May 2028.
- In the IVDR decision, point (1) of the Annex, i.e. the arrangement for removing references to the old version of EN ISO 11137-1, applies from 10 May 2028.
References to the new versions are incorporated into the corresponding harmonised standards lists upon publication of these decisions.
4. Impact of the Harmonised Standards Update on Medical Device Companies
This update covers multiple technical fields of medical devices, and different types of manufacturers need to focus on different content.
| Company and product type | Standards to focus on | Key points to watch |
|---|---|---|
| Radiation-sterilised medical devices | EN ISO 11137-1:2026 | Development, validation and routine control of sterilisation processes |
| Companies conducting clinical investigations in human subjects | EN ISO 14155:2026 | Good clinical practice requirements for clinical investigations |
| Implantable medical devices | EN ISO 10993-6:2026 | Evaluation of local effects after implantation |
| EO-sterilised medical devices | EN ISO 10993-7:2026 | Evaluation of ethylene oxide sterilisation residuals |
| Washer-disinfectors | EN ISO 15883-6:2026 | Requirements and tests for thermal disinfection equipment |
| Medical laser equipment | EN IEC 60601-2-22:2020 and A11:2026 | Basic safety and essential performance of laser equipment |
| Non-laser light source equipment | EN IEC 60601-2-57:2026 and A11:2026 | Basic safety and essential performance of non-laser light source equipment |
| Medical connectors | EN ISO 80369-1:2026 | General requirements for small-bore connectors for liquids and gases |
For companies that have already obtained CE MDR/IVDR certification or are preparing for EU registration, it is recommended to verify the applicability of standards based on actual product conditions. Particular attention should be paid to the standard versions cited in existing technical documentation, as well as the applicability of existing test and validation data in relation to the new versions.
5. What Should Manufacturers Prepare in Advance?
In view of this harmonised standards adjustment, companies are advised to focus on the following actions:
1. Review the existing standards list
Check the standard designations and versions cited in product technical documentation, declarations of conformity (DoC), test reports and related technical materials to confirm whether they involve the standards updated this time.
2. Assess differences between the old and new standards
For products already tested or validated against the old standard versions, assess whether the existing technical documentation remains applicable in light of the specific content of the new versions, and whether additional validation or testing is needed.
3. Pay attention to sterilisation-related documentation
For medical devices using radiation sterilisation or ethylene oxide sterilisation, pay particular attention to the updates of EN ISO 11137-1:2026 and EN ISO 10993-7:2026.
4. Pay attention to changes in the clinical trial standard
Companies conducting clinical investigations of medical devices should follow the publication of EN ISO 14155:2026 and assess its impact on clinical investigation documentation and implementation.
5. Plan the standards transition in advance
Although the removal of references to the existing standards is deferred to 10 May 2028, companies should familiarise themselves with the requirements of the new versions in advance and reasonably schedule updates of technical documentation and any necessary validation work.
Official regulatory documents
1. Commission Implementing Decision (EU) 2026/2479 (MDR): http://data.europa.eu/eli/dec_impl/2026/2479/oj
2. Commission Implementing Decision (EU) 2026/2481 (IVDR): http://data.europa.eu/eli/dec_impl/2026/2481/oj