Home > News Center > Indonesia Medical Device Registration

Indonesia Medical Device Registration

11 月 26, 2025 Registration Insights 0 views

Indonesia Medical Device Registration (KEMENKES / MoH RI)

1. Regulatory Authority & Framework

Indonesia regulates medical devices under:

  • Regulation of the Ministry of Health (MoH)
  • Permenkes 62/2017 (medical device distribution & licensing)
  • Permenkes 14/2021 (risk classification)
  • Regulation 16/2020 (electronic medical device systems)

Oversight bodies:

  • KEMENKES – Indonesia Ministry of Health
  • Ditjen Farmalkes – Directorate General of Pharmaceutical & Medical Devices
  • Digital platforms:
    • OSS-RBA – business licensing
    • e-Regalkes – medical device registration portal

2. Device Classification (Class A/B/C/D)

Indonesia follows a GHTF / ASEAN-aligned system:

ClassRisk LevelExamples
Class ALowNon-sterile bandages, basic tools
Class BLow–ModerateInfusion sets, suction pumps
Class CModerate–HighBlood glucose meters, HF surgical devices
Class DHighVentilators, implants, surgical robots

Note: IVDs also follow risk classification A–D.

3. Registration Routes & Requirements

All foreign devices must obtain:

  1. Local Authorized Representative (LAR)
  2. MoH Distribution License
  3. Product Registration Number (AKL / AKD)

Registration types:

  • AKL → Imported medical devices
  • AKD → Locally manufactured devices
  • PKRT → Household/consumer medical supplies (separate route)

4. Local Authorized Representative (LAR / License Holder)

Foreign manufacturers must appoint an Indonesian company with:

  • IDAK license (Medical Device Distributor License)
  • NIB (Business Identification Number) via OSS-RBA
  • Responsibilities include:
    • Product registration
    • Import permit & customs
    • Post-market surveillance
    • AE reporting & recalls
    • Ensure Bahasa Indonesia labeling compliance

One LAR = one registration.
Multiple LARs allowed, but each needs separate AKL numbers.

5. Dossier Requirements (Indonesia CSDT-aligned)

Submission is done via e-Regalkes. Required documentation includes:

Administrative Documents

  • Power of Attorney
  • Letter of Authorization (LOA)
  • Free Sale Certificate / Market Authorization from reference countries
  • ISO 13485 of manufacturer
  • Manufacturer license
  • Product confirmation letter
  • Declaration of Conformity

Technical Documents (CSDT Format)

  • Device description & intended use
  • Design verification & validation data
  • Biocompatibility data
  • Electrical safety (IEC 60601 series)
  • Software documentation (IEC 62304)
  • Cybersecurity (if software-driven)
  • Sterilization validation
  • Risk management (ISO 14971)
  • Clinical evaluation (CER)
  • Labeling & IFU (Bahasa Indonesia)
  • PMS plan

6. Fees & Timelines (Typical)

Official MoH Fees

  • Class A: ~IDR 1–3 million
  • Class B: ~IDR 3–5 million
  • Class C: ~IDR 5–7 million
  • Class D: ~IDR 7–10 million

Review Timelines (Typical)

  • Class A: 1–3 months
  • Class B: 3–6 months
  • Class C/D: 6–9+ months
    Timelines depend heavily on dossier quality & MoH queue.

Fast-track possible for products approved in reference countries (US/EU/CA/AU/MY/SG/etc.).

7. Labeling & IFU Requirements

Labeling must be compliant with Indonesian rules:

  • Device name/model
  • Manufacturer & LAR details
  • Country of origin
  • Lot / serial number
  • Manufacturing/expiry date
  • Storage & handling instructions
  • Bahasa Indonesia mandatory
  • IFU in Bahasa Indonesia (local translation can be provided on sticker or booklet)

8. Importation Requirements

Steps for importing:

  1. NIB + IDAK license
  2. MoH Registration Number (AKL)
  3. Customs clearance
  4. Import report via e-LKPP (if applicable)

High-risk devices (Class C/D) may require testing certificates at customs or additional declarations.

9. Post-Market Obligations

Indonesia has strict PMS responsibilities:

  • Adverse event reporting
  • Field safety corrective actions (FSCA)
  • Product recall procedures
  • Distribution record-keeping
  • Annual device availability reporting

10. Notes for Your Device Portfolio (Consulting View)

Device TypeExpected ClassIndonesia Requirements
Soft contact lensesClass CRequires biocompatibility, clinical evaluation, CE/FDA speeds pathway
Surgical robots / AR/MR platforms (SyngAR™)Class DFull dossier + cybersecurity + software safety + IEC 60601 electrical safety
High-frequency electrosurgical devicesClass C/DEMC + electrical safety critical; CER required
Blood glucose meters & stripsClass CISO 15197 validation required; local lab testing rarely required
Serum preparation device (single-use)Class B/CSterilization validation + performance data

11. Key Advantages of Indonesia Market

  • Population: 275+ million, largest ASEAN market
  • High reliance on imported medical devices (>90%)
  • ASEAN CSDT alignment → easier harmonization with MY, SG, VN, TH
  • CE/FDA products typically receive smoother review

Author:Grzan