Clinical Evaluation and Clinical Trials in Israel
Updated: 2026-11-11 · GRZAN Regulatory Team · Verification date 2026-10-20
1. Key takeaways
The legal basis for clinical trials in Israel is the Public Health Regulations (Clinical Trials in Humans), 5741-1980. The sequence of determination has three steps. First, examine whether the trial qualifies as a special trial: research conducted with a device already approved in a reference country, at the approved doses and for the approved indications, is a special trial and requires only the approval of the institutional Helsinki committee and the head of the institution, without Ministry of Health approval. Second, a non-special trial additionally requires the approval of the Ministry of Health Director General (represented by the clinical trials unit). Third, multi-centre research involving three or more Israeli institutions requires, since January 2020, the additional approval of the National Committee for Multi-Centre Research (Ministry of Health Guideline No. 168, pilot project). Trials must be registered on the Ministry of Health website, sponsors must update at least quarterly, and a clinical safety report must be submitted 1 year after completion.
- The special/non-special determination comes first because it fixes the length of the entire approval chain.
- Devices using the reference-country pathway can run local clinical verification at institutional level only, which shortens the cycle markedly (practical estimate: 2–4 months).
- Registration and reporting duties fall on the sponsor and run on a separate track from AMAR registration.
- Article 4(8) of the Medical Equipment Law provides a lawful channel for clinical evaluation in a limited number of patients while the Israeli registration application is under review.
2. Legal basis
The table below records the regulations, the companion guidelines, the international standards and the parallel laws that frame clinical trials in Israel.
| Regulation name | Public Health Regulations (Clinical Trials in Humans), 5741-1980 |
| Reference / number | 5741-1980 |
| Publication date | 1980 (made under the Public Health Ordinance, subsequently amended several times) |
| Provisions | Classification provisions for special and non-special trials (Fourth Schedule to the Regulations); Article 3B (assessment by the supreme committee) |
| Companion guidelines | Ministry of Health Clinical Trials Guideline No. 14 (2020); Ministry of Health Guideline No. 168 (National Committee for Multi-Centre Research, January 2020) |
| International standards | Declaration of Helsinki; ICH-GCP E6; ISO 14155-1/-2 (clinical investigation of medical devices in human subjects) |
| Parallel laws | Genetic Information Law, 2000; Patient’s Rights Law, 1996; Protection of Privacy Law, 5741-1981 |
3. Expert insights
For device companies, the most valuable single feature is the recognition of a special trial: research conducted with a device already approved for marketing in a reference country (the United States, member states of the European Union, Switzerland, Norway, Iceland, Australia, New Zealand, Japan), at the approved doses and for the approved indications, is a special trial and need not pass through Ministry of Health level approval. This means that most local clinical verification undertaken to support Israeli registration can be completed at institutional level, with a markedly shorter cycle (practical estimate: 2–4 months).
Scenarios that trigger the non-special classification include: use of a device not approved in any reference country, conduct beyond the approved indications or doses, research involving human genetics, and research related to assisted reproduction. The last two categories additionally require submission to the supreme Helsinki committee for assessment, which lengthens the chain further and should be identified at the planning stage rather than after the protocol is fixed.
The second point of interest is the registration and reporting obligations: trials that are controlled and prospective, involve medical intervention, and examine health outcomes must be registered on the Ministry of Health website; the sponsor registers after obtaining ethics committee approval (form 6) and obtains the institutional authorisation to proceed (form 7); the information must be reviewed and updated at least quarterly; and a clinical safety report is due one year after completion of the research. These obligations rest on the sponsor and run on a line separate from AMAR registration, so they need their own owner and calendar.
The third point of interest is the link to Article 4(8) of the Medical Equipment Law: devices already approved in a reference country whose Israeli registration application is under review may be used by health institutions for clinical evaluation in a limited number of patients. This is the lawful channel of registration pending plus clinical evaluation first (see article 8), and it is often the deciding factor in planning the Israeli entry sequence.
4. Practical recommendations
- Make the special/non-special determination first. This step decides the length of the approval chain and should be completed before the protocol is finalised.
- Ensure reference-country approvals cover the trial indications. The moment the trial moves beyond an approved indication, it falls into the non-special category.
- Plan multi-centre research early. Research at three or more institutions must go through the National Committee for Multi-Centre Research, so scheduling must start well in advance.
- Manage sponsor duties separately. Set independent reminders for the three obligations: registration, quarterly updates, and the clinical safety report one year after completion.
5. Verification checklist
- □ The special/non-special trial determination has been completed and its basis is retained on file
- □ The device used in the trial has reference-country approvals covering the trial indications
- □ Approvals of the institutional Helsinki committee and the head of the institution have been obtained
- □ For non-special trials, Ministry of Health (clinical trials unit) approval has been obtained
- □ Multi-centre research at three or more institutions has been submitted to the National Committee for Multi-Centre Research
- □ Registration on the Ministry of Health website (forms 6/7) is complete, with reminders set for quarterly updates and the report after 1 year
Regulatory information verified as of 29 October 2026. The regulation names, numbers, publication dates and provisions cited in this article were checked against the official Israeli legal databases and authoritative public sources on that date; AMAR procedural documents are updated frequently, so before any formal submission the current version on the Ministry of Health website prevails.
How GRZAN can help. GRZAN provides medical device and IVD registration, quality system, authorised representative and local testing support for the Israeli market. Our team prepares MOH-compliant dossiers, and supports post-market vigilance obligations. Business enquiries: info@grzanglobal.com
Disclaimer
Prepared by GRZAN from publicly available regulation. It is provided for general information only and does not constitute legal advice. Legislation and official fees are subject to change by the competent authority.
About GRZAN
GRZAN (Global Regulatory Zone Access Navigator) — the global market-access navigator for medical devices and IVDs.
GRZAN is a specialist consultancy for medical device and IVD market access, providing end-to-end regulatory solutions across the product lifecycle and making international market entry simpler and faster.
Key figures. More than 25 wholly owned subsidiaries worldwide covering 50+ countries and regions; chosen by 100+ listed and leading Chinese device manufacturers, with 4,000+ successful cases; 12+ years in the sector and 200+ regulatory training sessions and seminars delivered.
What we do. Global market access: multi-country registration programmes, technical documentation, regulatory advice. Clinical evidence: clinical evaluation reports (CER), usability studies, overseas clinical investigations. Quality systems: ISO 13485, MDSAP, FDA QMSR and BGMP implementation and audit readiness. Authorised representative and licence-holder services across Southeast Asia, Latin America, the Middle East, Africa, Europe and North America.
Why GRZAN. A real operating entity, with the certificate held by the manufacturer: our direct overseas subsidiaries act as the compliant local holder, so the regulatory relationship stays clear and you keep control rather than being tied to a distributor. Direct access to the team: no time-zone gap, no language barrier, no cultural gap. Review points anticipated: we know what FDA 510(k), EU MDR, Southeast Asian, Latin American and Middle Eastern reviewers look for, which shortens timelines and reduces deficiency letters. Pathway planning: pre-decision analysis and risk assessment before you commit.
Every engagement rests on three commitments: efficiency through pre-submission review, certainty through a clear pathway, and stability through a licence-holder that stays in place.
Take your devices global with GRZAN
We work with manufacturers worldwide to open new markets with a clear regulatory pathway.
Contact us