Recognition of ARN Registrations Under the GBT

Updated: 2026-11-12 · GRZAN Regulatory Team · Verification date 2026-10-20

1. Key takeaways

Acuerdo No. 0631-ARSA-2023, the Regulation for the Sanitary Control of Medical Devices and Other Devices of Sanitary Interest, provides in Article 47 that ARSA may recognise (podrá reconocer) the sanitary registrations of devices issued by national regulatory authorities (ARN) of maturity level 3 or 4, with maturity assessed according to the Global Benchmarking Tool (GBT) used by the World Health Organization (OMS) to evaluate national regulatory systems. The provision explains that the purpose of this requirement is to harmonise international standards of quality, safety and efficacy. Section I of Article 3 defines the GBT as the worldwide tool of the OMS for evaluating national regulatory systems for medical products, and separately defines the strictly regulated authority (Autoridad Reguladora estricta), used for the emergency use authorisation pathways of Article 42 and Articles 72 and 73. The GRZAN regulatory team notes that the threshold of Article 47 — maturity level 3 or 4 — is clearly lower than the strictly regulated authority standard, making this the most worthwhile international reliance pathway in this market; but the provision uses may rather than shall, so whether recognition is granted remains a case-by-case judgment of ARSA.

  • ARSA may recognise device registrations issued by ARNs of GBT maturity level 3 or 4.
  • The stated purpose is to harmonise international standards of quality, safety and efficacy.
  • The GBT is defined in Article 3 as the OMS tool for evaluating national regulatory systems.
  • The strictly regulated authority definition serves the emergency use pathways of Articles 42, 72 and 73.
  • Recognition is discretionary, not mandatory, and is decided case by case.

2. Legal basis

The provisions below frame the recognition pathway, the definitions it rests on, and the requirements it leaves untouched.

LevelInstrumentProvisionKey point
RegulationAcuerdo No. 0631-ARSA-2023, Regulation for the Sanitary Control of Medical Devices and Other Devices of Sanitary InterestArticle 47Registrations issued by ARNs of GBT maturity level 3 or 4 may be recognised, in order to harmonise international standards
RegulationAcuerdo No. 0631-ARSA-2023Article 3, Section IGBT stands for Herramienta Mundial de la OMS para la Evaluación de los Sistemas Regulatorios Nacionales de Productos Médicos
RegulationAcuerdo No. 0631-ARSA-2023Article 3, Section IIStrictly regulated authority: one assessed at the highest maturity level by the OMS / OPS prequalification tool
RegulationAcuerdo No. 0631-ARSA-2023Article 42.1, 2; Articles 72, 73.1Emergency use authorisations from strictly regulated authorities underpin exceptional import and the AEG / AENG routes
RegulationAcuerdo No. 0631-ARSA-2023Article 31The classification report remains a precondition of registration; Article 47 does not waive it
RegulationAcuerdo No. 0631-ARSA-2023Article 43Dossier requirements by class; Article 47 provides no reduction of documents
RegulationAcuerdo No. 0631-ARSA-2023Article 90The regulation will be revised and supplemented as international regulatory practice advances, leaving room for the reliance pathway to expand

3. Expert insights

Insight one: maturity level 3 or 4 and the strictly regulated authority are two different thresholds. Article 47 uses GBT maturity levels 3 or 4, while the strictly regulated authority defined in Article 3 requires the highest maturity level (usually corresponding to level 4). The two serve different pathways in the text: the former applies to recognition of registrations, the latter to the acceptance of emergency use authorisations. Companies should cite the correct threshold in their arguments and not confuse the two.

Insight two: the wording is podrá reconocer — may recognise — not shall recognise. This makes Article 47 an enabling norm, not an obligatory one: ARSA retains case-by-case discretion. The practical consequence is that holding a registration from a maturity level 4 country cannot be advanced as a ground for exemption from review; it should instead be submitted as supporting evidence, alongside the full set of ordinary documents required under Article 43 and below.

Insight three: Article 47 provides no reduction of documents. The provision only says registrations may be recognised; it lists no documents that may be waived and sets no exception to validity periods. This differs from the equivalent documents mechanism of Article 46.5, which expressly names 5 types of documents that may substitute when the prescribed documents cannot be submitted (including the CE certificate). Article 47 is therefore better suited to accelerating review than to cutting paperwork.

Insight four: the classification report precondition has not been waived. Article 31 requires ARSA’s own classification report before any sanitary registration, and Article 47 makes no exception to this. This confirms the design of Article 29: the risk class is determined by ARSA itself on the basis of intended use, and is not waived because another country has already classified the device.

Insight five: Article 90 reserves room for the reliance pathway to expand. The provision states that the regulation will be revised, updated or supplemented as international regulatory practice for medical devices advances, on the condition that scientific evidence supports the change. Together with the 180-day implementing-legislation window granted to ARSA by Article 93, implementing rules for Article 47 may be expected; the operational details of this article should be reviewed quarterly.

4. Practical recommendations

  • Where a registration from a GBT maturity level 3 or 4 country is already held, submit it with the dossier as supporting evidence.
  • Cite the thresholds precisely in arguments: maturity level 3 or 4 for registration recognition, strictly regulated authority for emergency use authorisations.
  • Do not reduce the dossier because of an existing foreign registration; prepare the full set of documents under Article 43 and below.
  • Still obtain ARSA’s own classification report first under Article 31; do not expect it to be waived.
  • Review quarterly whether ARSA has issued implementing rules or operational guidance for Article 47.
  • Add a page on international reliance at the front of the dossier, listing the foreign registration, its issuing authority and the maturity basis.

5. Verification checklist

  • □ The GBT maturity level of the foreign issuing authority has been confirmed
  • □ The foreign registration has been submitted with the dossier as supporting evidence
  • □ The thresholds are cited accurately (maturity level 3 or 4 / strictly regulated authority)
  • □ The ordinary dossier documents have not been reduced on account of the foreign registration
  • □ ARSA’s classification report has been obtained under Article 31
  • □ A quarterly review mechanism is set for implementing rules on Article 47

Further reading: [Article 09 — The four risk classes](/honduras-medical-device-registration/four-risk-classes-i-iia-iib-iii/) | [Article 02 — The four layers of legal sources](/honduras-medical-device-registration/honduras-medical-device-legal-framework/) | [Article 24 — What to add for Clase III](/honduras-medical-device-registration/class-iii-additional-requirements/)

Regulatory information verified as of 29 October 2026.

How GRZAN can help. GRZAN provides medical device and IVD registration, quality system, authorised representative and local testing support for the Honduran market. Our team manages Secretariat of Health (SESAL) registration applications, prepares Spanish-language dossiers, and supports post-market vigilance obligations. Business enquiries: info@grzanglobal.com

Disclaimer

Prepared by GRZAN from publicly available regulation. It is provided for general information only and does not constitute legal advice. Legislation and official fees are subject to change by the competent authority.

About GRZAN

GRZAN (Global Regulatory Zone Access Navigator) — the global market-access navigator for medical devices and IVDs.

GRZAN is a specialist consultancy for medical device and IVD market access, providing end-to-end regulatory solutions across the product lifecycle and making international market entry simpler and faster.

Key figures. More than 25 wholly owned subsidiaries worldwide covering 50+ countries and regions; chosen by 100+ listed and leading Chinese device manufacturers, with 4,000+ successful cases; 12+ years in the sector and 200+ regulatory training sessions and seminars delivered.

What we do. Global market access: multi-country registration programmes, technical documentation, regulatory advice. Clinical evidence: clinical evaluation reports (CER), usability studies, overseas clinical investigations. Quality systems: ISO 13485, MDSAP, FDA QMSR and BGMP implementation and audit readiness. Authorised representative and licence-holder services across Southeast Asia, Latin America, the Middle East, Africa, Europe and North America.

Why GRZAN. A real operating entity, with the certificate held by the manufacturer: our direct overseas subsidiaries act as the compliant local holder, so the regulatory relationship stays clear and you keep control rather than being tied to a distributor. Direct access to the team: no time-zone gap, no language barrier, no cultural gap. Review points anticipated: we know what FDA 510(k), EU MDR, Southeast Asian, Latin American and Middle Eastern reviewers look for, which shortens timelines and reduces deficiency letters. Pathway planning: pre-decision analysis and risk assessment before you commit.

Every engagement rests on three commitments: efficiency through pre-submission review, certainty through a clear pathway, and stability through a licence-holder that stays in place.

Take your devices global with GRZAN

We work with manufacturers worldwide to open new markets with a clear regulatory pathway.

Contact us
WhatsApp
QR Code
WhatsApp QR Code
Scan to chat on WhatsApp
Phone
Call
Office Mon-Fri 9:00-18:00
0755-88659477
Mobile 24/7 Service
+86 15816864648
Email
Mail